Rigid Underlays - Discontinuous Roofing Sheets

Homepage CE Services Waterproofing Materials Rigid Underlays - Discontinuous Roofing Sheets

Rigid Underlays - Discontinuous Roofing Sheets

Rigid Underlays- Discontinuous Roofing Sheets - EN 14964

Systems of assessment and verification of constancy of performance (AVCP) to be applied for bitumen-based rigid underlays used under non-continuous roof coatings are determined according to the following tables in accordance with the definitions given in the EN 14964 standard.

Product

Intended Uses

Level or Classes

AVCP system(s)

Rigid Underlays- Discontinuous Roofing Sheets

For uses subject to regulations on dangerous substances

-

3

For uses subject to reaction to fire regulations

(A1, A2, B, C)*

1

(A1, A2, B, C)**, D, E

3

 F

4

* Products/materials for which a clearly identifiable stage in the production process results in an improvement of the reaction to fire classification (e.g. an addition of fire retardants or a limiting of organic material).
** Products/materials not covered by footnote (*).
*** Products/materials which do not require to be tested for reaction to fire, i.e. those of Class A1 in accordance with Decision 96/603/EC, as amended and those classified without further testing (CWFT)

Systems of assessment and verification of constancy of performance (AVCP) - EN 14964

As the bitumen-based sheets “rigid underlays- discontinuous roofing sheets” will have reaction to fire class E; it turns out that the systems of assessment and verification of constancy of performance (AVCP) of these products is system 3. Only fire-related properties of the products with reaction to fire class F need to be evaluated within system 4. No fire test is required for class F products. Accordingly, in the EN 14964 standard, which covers the relevant product groups, the duties of the producers within the scope of system 3 are determined by the table given below.

Tasks

Content of the task

Tasks under the responsobility of the manufacturer

Factory product control (FPC)

Parameters related to characteristics of Table ZA.1 and ZA.1.3

Initial type testing by the manufacturer

All relevant characteristics of Table ZA.1, relevant for the intended use, except reaction to fire and dangerous substances

Initial type testing by a notified test laboratory

Reaction to fire (A1,A2,B,C)**, D,E and dangerous substances

Duties within the scope of system 3 for EN 14964

Tests Required to be Performed by Notified Laboratories: For these products included in System 3, the control activities of the notified test laboratory, under the responsibility of the manufacturer, are limited to dangerous substance and reaction to fire. The manufacturer is responsible for the application of other tests given in the ZA.1 table.

Behavior in the Face of Fire (Basic Requirements 2: Safety in case of fire)

EN ISO 11925-2: Reaction to fire tests - Ignitability of products subjected to direct impingement of flame - Part 2: Single-flame source test

EN 13501-1: Fire classification of construction products and building elements - Part 1: Classification using data from reaction to fire tests