Waterproofing Membranes Including Basement Tanking Sheets- EN 13969 & EN 13967
Systems of assessment and verification of constancy of performance (AVCP) are determined according to the table below given in EN 13969 and EN 13967 standards. Systems of assessment and verification of constancy of performance (AVCP), producer and notified body responsibilities are the same as waterproofing sheets used on roofs. The only difference between the conformity assessment procedures is related with reaction to fire classifications. Since there is no risk to exposure to external fire at below grade applications, external fire performance is not applicable for these products.
Product |
Intended Uses |
Level or Classes |
AVCP system(s) |
Waterproofing sheets |
Damp proofing for buildings, including basement tanking subject to reaction to fire |
(A1, A2, B, C)* |
1 |
(A1, A2, B, C)**, D, E |
3 |
||
F |
4 |
||
Damp proofing for buildings, including basement tanking b |
- |
2+ |
|
* Products/materials for which a clearly identifiable stage in the production process results in an improvement of the reaction to fire classification (e.g. an addition of fire retardants or a limiting of organic materials). |
|||
b: Because all damp proofing sheets have a requirement on watertightness, all products covered by this standard come under attestation system 1 or 2+. System 3 and 4 in Table ZA.2 indicate only that the characteristic 'reaction to fire' is either tested by a notified test laboratory or is not tested at all. |
Tasks |
Content of the task |
||
Tasks under the responsibility of the manufacturer |
Factory product control (FPC) |
Parameters related to all relevant characteristics of ZA.1. |
|
Initial type testing by the manufacturer |
All relevant characteristics of Table ZA.1 except reaction to fire. |
||
Initial type testing by a notified test laboratory |
Reaction to fire (A1, A2, B, C)**, D, E |
||
Tasks for the notified FPC certification body |
Certification of FPC on the basis of |
Initial Inspection of factory and FPC |
Parameters related to all relevant characteristics of Table ZA.1, in particular watertightness |
Continuous surveillance, assessment and approval of FPC |
Parameters related to all relevant characteristics of Table ZA.1, in particular watertightness |
Tests to be Performed by Notified Laboratories: The duties of the notified body, which will carry out conformity evaluation processes of bitumen and synthetic based sheets used for basement tanking within the scope of System 2+, are limited to factory production control, continuous surveillance and inspection. In addition, a notified laboratory under the responsibility of the manufacturer is required to determine the reaction to fire of the product.